Related Experiment Video
Updated: Jan 24, 2026

DNA Electrophoresis Using Thiazole Orange Instead of Ethidium Bromide or Alternative Dyes
Published on: March 31, 2019
Serum protein media are important factors in the manual hexadimethrine bromide (polybrene) test, experience in China
1Department of Blood Transfusion, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, No. 1277, Jiefang Avenue, 430022 Wuhan, Hubei Province, China. liu_feng_email@sina.com
Background And Objectives:
The use of the manual hexadimethrine bromide (polybrene) test in routine cross-matching after accurately detecting cell grouping and irregular antibodies is prevalent in China. This article reports the importance of serum protein mediums in the performance of the manual hexadimethrine bromide test.
Materials And Methods:
Blood group O red blood cells and Blood group AB and Rh positive serum were collected at random from healthy blood donators, IgG anti-D serum separated from pregnant woman, then tested with each other by the manual hexadimethrine bromide methods in routine tests and some designed corresponding tests with IgG, IgM anti-D monoclonal diagnostic reagents and some serum protein components.
Results:
Red blood cells that were adjusted to 3-5% suspension by normal saline then only added in 0.7 ml low ionic medium (LIM) and two drops of polybrene solution adhere to the surface of test tubes' bottom when centrifuged, so it was difficult to perform the next approach, but the adherence disappeared when red blood cells' concentrations exceeded 20-30%. Rh positive red blood cells coated by anti-D have the same phenomenon. This adherence can be prevented by serum medium diluted from 1:128 to 1:1024 times by normal saline and hemoglobin medium diluted from 1:32 to 1:128 times, but not by albumin or immunoglobulin medium. The denary logarithm values of the greatest inhibited dilutions of serum and hemoglobin elution between antibody sensitizing red blood cells and the same pre-sensitizing red blood cells tests were no significant difference (P value > 0.05).
Conclusions:
The whole serum or serum protein mediums are important factors that can influence successfully performance of the manual hexadimethrine bromide test. So appliance of the manual hexadimethrine bromide test to immunohematology laboratory, such as when performing titrations of serum or plasma, or when testing eluates for antibody activity, this adherence must be considered.
Related Concept Videos
Factors Affecting Protein-Drug Binding: Protein-Related Factors
The physicochemical properties of a drug play a significant role in its ability to bind to proteins. Lipophilic drugs, which dissolve in fats, oils, and lipids, can be...
Factors Affecting Protein-Drug Binding: Drug-Related Factors
One crucial factor in drug-protein binding is the drug's lipophilicity or its affinity for fat. More lipophilic drugs tend to have higher binding extents. For example, highly lipophilic drugs like cloxacillin exhibit substantial protein binding, with as much as 95% of the drug binding to proteins. In...
Factors Affecting Protein-Drug Binding: Patient-Related Factors
Age stands as a key determinant in protein-drug binding. Neonates, characterized by low albumin content, experience heightened concentrations of unbound drugs such as phenytoin and...
Transcription Factors
Factors Affecting Protein-Drug Binding: Drug Interactions
Displacement interactions can have varying outcomes, ranging from toxicity to virtually...
Transcription Elongation Factors
The transcription elongation is regulated via pausing of RNA polymerase on several occasions during transcription. In bacteria, these halts are necessary because the transcription of DNA into mRNA is coupled to the translation of that mRNA...

