Purpose:
When patients are moved from the supine to the lateral decubitus position, the double-lumen endobronchial tube (DLT) is often displaced. The aim of this study was to determine whether a DLT is displaced when there are no movements of the head and neck.
Methods:
One hundred patients scheduled for elective thoracic surgery were randomly divided into control and brace groups. Only a left-sided DLT was used during the study. All patients in the brace group wore a neck collar before the positional change. Using a fibreoptic bronchoscope, the distance from the tracheal opening to the main carina and from the bronchial opening to the bronchial carina was measured in the supine and lateral decubitus positions.
Results:
Displacement of the DLT (mean +/- SD) during a change from the supine to the lateral decubitus position was greater in the control group (6.3 +/- 5.5 mm in the trachea; 2.4 +/- 3.6 mm in the bronchus) than in the brace group (2.2 +/- 3.9 mm in the trachea; 0.6 +/- 3.1 mm in the bronchus); (P < 0.001). The incidence of clinically significant displacement, greater than 5 mm from the initial correct position, was higher in the control group than in the brace group (48% vs 12%, P < 0.001).
Conclusion:
By restricting head and neck movements with a neck brace, the DLT displacement could be minimized while positioning patients for thoracotomy. The main cause of the DLT displacement during lateral positioning appears to be related to movement of the head and neck.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...