Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Importance of Debye and Keesom interactions in separating m-xylene and p-xylene in GC-MS analysis utilizing PEG
Hiromitsu Kanai1, Veronica Inouye, Lester Yazawa
1Measurement Standards Br., Hawaii State Department of Agriculture, Honolulu, HI, 96813, USA.
Abstract:
In electron impact gas chromatography (GC)-mass spectrometry analysis of a complex mixture, such as gasoline, two coeluting solutes can be distinguished if each has a unique major ion. The boiling-point difference between m-xylene and p-xylene, which also has identical major ions (mz-1: 91 and 106 Da), is 0.77 degrees C. These cannot be separated even on a crossed-linked polydimethylsiloxane capillary column, which has a minimum of 5000 plates/m. They are separated on a crossed-linked polar polyethylene glycol (PEG) capillary column. GC separation on a stationary phase depends on the relative strengths of solute-solute, stationary phase-stationary phase, and solute-stationary phase interactions. Although the calculated molar electronic polarization and refractivity factor of Lorenz-Lorentz equation for m-xylene and p-xylene are nearly equal because of its greater dipole moment difference (0.30 and 0.02), the calculated orientation polarization of m-xylene is 80 times greater than p-xylene. This implies the dipole reinforcement through inductive polarization by the hydroxyl of PEG stationary phase molecules is greater on m-xylene than p-xylene. In addition, as the permanent dipole moment of m-xylene is 15 times greater than p-xylene, m-xylene has a stronger Keesom interaction with PEG. In order for m-xylene and p-xylene to solvate in PEG, analytes must overcome the PEG-PEG Keesom/hydrogen bonding interaction forces. Physical and chemical parameters indicate that compared with p-xylene, m-xylene has a greater Debye-Keesom interaction tendency with PEG molecules. This is supported by the 0.12-min. retention-time difference between them.
More Related Videos
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
05:45Capillary Electrophoresis-based Hydrogen/Deuterium Exchange for Conformational Characterization of Proteins with Top-down Mass Spectrometry
Published on: June 8, 2021
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...