The European Society of Hypertension (ESH) has issued guidelines for the detection and treatment of hypertension. According to these guidelines, normal 24-h ambulatory blood pressure (ABP) is defined as lower than 125/80 mmHg. Another publication of ESH recommendations for blood pressure (BP) measurement defines normal awake and asleep blood pressure as lower than 135/85 and 120/70 mmHg, respectively. Our aim was to investigate the compatibility of these two recently proposed ABP cutoffs in clinical practice. We analysed 1495 consecutive ABP measurements. In all, 56% of the subjects were female; age 58 +/- 16 years; body mass index 27 +/- 4 kg/m(2); clinic BP 151+/-22/84 +/- 13 mmHg. Two-thirds were treated for hypertension, and 11% for diabetes. Subjects were classified as having normal 24-h BP if the corresponding value was <125/80 mmHg. Normal awake-sleep BP was diagnosed if awake BP was <135/85 mmHg and sleep BP was <120/70 mmHg. Concordance between the cutoffs was found in 93% of the subjects. Among the 7% discordant subjects, 4.5% were hypertensive applying the 24 h, but not awake-sleep, BP values, whereas only 2.5% were hypertensive according to awake-sleep, but not 24 h, BP values (P < 0.005). In Conclusion, in real-life ABP measurement, a good agreement was found between two recently issued ABP normality definitions. However, some subjects are classified as hypertensive only according to one of these methods, more often by the 24-h cutoff of 125/80. This discordance may be significant in large-scale clinical BP monitoring.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)