Related Experiment Videos
Agreement between peripheral anterior chamber depth evaluation using the van Herick technique and angle width
Kenji Kashiwagi1, Takaharu Tokunaga, Aiko Iwase
1Department of Ophthalmology, University of Yamanashi Faculty of Medicine, Yamanashi, Japan. kenjik@yamanashi.ac.jp
Japanese Journal of Ophthalmology
|April 20, 2005
Summary
The van Herick technique closely correlates with the Shaffer system for identifying narrow angles in Japanese eyes. This suggests the van Herick method is a viable, simple screening tool for narrow-angle glaucoma.
Area of Science:
- Ophthalmology
- Public Health
- Epidemiology
Background:
- Glaucoma is a leading cause of irreversible blindness worldwide.
- Early detection of narrow angles is crucial for preventing angle-closure glaucoma.
- Standardized methods for angle assessment are essential in large-scale screening.
Purpose of the Study:
- To evaluate the correlation between the van Herick system and the Shaffer system.
- To assess the utility of the van Herick technique for identifying narrow angles in a Japanese population.
Main Methods:
- A large-scale ophthalmic epidemiological survey of 14,779 Japanese subjects aged 40+.
- Initial screening using the van Herick technique to identify potential narrow angles (grades 1 and 2).
- Secondary gonioscopic examination by glaucoma specialists using the Shaffer system for definitive angle assessment.
Main Results:
- 923 eyes (6.2%) were identified as narrow-angle eyes by the van Herick technique.
- Of these, 426 eyes (65.9%) were confirmed to have angles as narrow as or narrower than Shaffer grade 2.
- Van Herick grade 1 showed a high concordance (86.3%) with Shaffer grade 2 or narrower.
Conclusions:
- The van Herick technique demonstrates a strong correlation with the Shaffer system.
- The van Herick method is a potentially useful and simple tool for screening narrow-angle eyes in the Japanese population.
- This finding supports the use of van Herick for efficient initial assessment in epidemiological studies.