Related Experiment Video
Updated: Aug 18, 2026

Fentanyl Analog Screening using LC-TIMS-TOF MS/MS
Published on: November 8, 2024
Determination of nalmefene by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
Wenfang B Fang1, David M Andrenyak, David E Moody
1Center for Human Toxicology, Department of Pharmacology and Toxicology, University of Utah, Salt Lake City, Utah 84112, USA.
Abstract:
Nalmefene is an opioid antagonist used in the treatment of alcoholism and opioid overdose. A highly sensitive method was developed to measure nalmefene in human and rabbit plasma and rabbit serum. Nalbuphine was used as internal standard. Liquid-liquid extraction was applied using n-butyl chloride/acetonitrile (4:1). High-performance liquid chromatography interfaced by electrospray ionization to a tandem mass spectrometer was used for quantitation. Primary validation experiments were conducted using human plasma then it was cross-validated in rabbit plasma and rabbit serum. Specificity (peak-area ratio of blank plasma or serum to its internal standard as percent of peak-area ratio of blank plasma or serum fortified with 0.1 ng/mL nalmefene to its internal standard) ranged from 2.09 to 5.29 with a mean of 3.21% for human plasma and from 4.08 to 6.63 with a mean of 5.55% for rabbit plasma and from 2.47 to 6.17 with a mean of 3.62% for rabbit serum. The mean recovery for nalmefene was 80% in human plasma. The calibration range was from 0.1 to 100 ng/mL. Intrarun accuracy of the lower limit of quantitation (0.1 ng/mL) in all matrices was within 18.0% of target with intrarun precision within 13.6%. At 0.3, 35, and 75 ng/mL, the intrarun accuracy in all matrices was within 11.9% of target with intrarun precision within 6.6%. The inter-run accuracy in human plasma was within 8.0% of target with inter-run precision within 6.6%. Nalmefene was stable in human and rabbit plasma and rabbit serum for up to 24 h at room temperature and in human plasma after three freeze-thaw cycles. Following intravenous injection of 5 mg/kg nalmefene to rabbits, the mean area under curve for 0 to 24 h was 1116 (ng)(mL)(-1)(h), and the mean plasma clearance was 67.9 (mL)(min)(-1)(kg)(-1).
More Related Videos
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Types of Detectors