Related Experiment Video
Updated: Aug 18, 2026

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
[A prospective randomized comparison between with or without instrumentation in short-level anterior discectomy and
Sheng-Fa Pang1, Mai Li, Shao-Bo Wang
1Department of Orthopedic, the Third Hospital of Peking University, Beijing 100083, China. panshengfa@vip.sina.com
Objective:
To evaluate anterior cervical plating in short-level anterior discectomy and autograft bone fusion.
Methods:
Eighty-one patients who underwent one- and two-level anterior cervical discectomy and fusion were randomized to 2 groups, with or without instrumentation. Among them, 55 patients were followed up. The mean follow-up time was (22 +/- 7) months. Fusion rate, disc height and cervical lordotic alignment were assessed by radiographs.
Results:
The improving rates were 68% in non-instrumented group and 58% in instrumented group, respectively (P > 0.05). The fusion rate was 93% in the non-instrumented group and 100% in the later one. The disc height was decreased (0.7 +/- 1.0) mm in the former group and increased (1.2 +/- 0.6) mm in the later one (P < 0.01). Although the postoperative cervical lordotic alignment was maintained better in instrumented group, the difference was not significant.
Conclusion:
Anterior cervical plating can make good influence on the result of anterior cervical discectomy and fusion in some degree.