Abstract:
Band broadening at high electric field strengths in capillary electrophoresis (CE), especially in wide capillaries, is often attributed to radial temperature gradients in the interior of the capillary caused by Joule heating. In some cases, however, a major cause of the lower separation efficiency could be the abrupt application of high electric field strength. We show that, with ethanol as background electrolyte solvent, initial abrupt voltage application introduces band broadening, which is especially pronounced in wider capillaries at high electric field and ionic strengths. With an appropriate initial voltage ramp this effect can be avoided. The effect of different voltage ramp up times on the separation efficiency of some anionic analytes was investigated with 50, 75 and 100 microm I.D. capillaries at field strengths of 1000-2000 V cm(-1). The results suggest that the band broadening associated with abrupt voltage application is of thermal origin and probably related to thermal volume expansion of the sample and background electrolyte solutions. The plate numbers calculated with a plate height model were in good agreement with the experimental values when a sufficiently long voltage ramp was employed. The dispersion due to axial temperature gradients was found to be very small under the experimental conditions used.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Column Efficiency: Rate Theory