Related Experiment Video
Updated: Aug 18, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Bioresorbable fixation devices for musculoskeletal injuries in adults
J S Jainandunsing1, M van der Elst, C C van der Werken
1Surgery, Reinier de Graaf Groep, Reinier de Graafweg 3-11, Delft, Zuid-Holland, Netherlands, 2600 GA. Jainandunsing@rdgg.nl
Background:
Bioresorbable implants for musculoskeletal injuries involving bone and ligaments in adults might have significant advantages compared to the conventionally used non-resorbable metal implants because they lead to a gradual transfer of the mechanical load from the implant to the healing bone and do not require a secondary removal operation. Tissue reactions may present a problem and bioresorbable screws are mechanically not as strong as their metal counterparts.
Objectives:
To compare bioresorbable implants to non-resorbable implants with respect to functional outcome, wound infections, other complications and reoperation rate,in the fixation of bone fractures or re-attachment of soft tissue to bone.
Search Strategy:
We searched the Cochrane Musculoskeletal Injuries Group Specialised Register (March 2004), the Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 1, 2004), MEDLINE (1966 to February 2004), EMBASE (1988 to February 2004), BL Inside (to February 2004), SIGLE (to February 2004), the metaRegister of Controlled Trials at http//:controlled-trials.com/, and reference lists of articles.
Selection Criteria:
Randomised controlled trials (RCTs) and quasi-randomised trials, comparing bioresorbable osteosynthesis with metal osteosynthesis (including titanium and stainless steel implants) were included.
Data Collection And Analysis:
Review authors independently assessed trial quality and extracted data. Data were pooled where relevant and possible. Sub-analyses for specific type of fractures and for specific type of tissue reactions were performed. Requests for more information were sent to trialists.
Main Results:
No significant difference between the bioresorbable and other implants could be demonstrated with respect to functional outcome, infections and other complications. Reoperation rates were lower in some of the groups of people treated with bioresorbable implants.
Authors' Conclusions:
In a selected group of compliant patients with simple fractures, the use of bioresorbable fixation devices might be advantageous.