Determination of metal concentration in fat supplements for swine nutrition by atomic absorption spectroscopy
Related Experiment Video
Updated: Jul 31, 2026

Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Marina Cocchi1, Valerio Faeti, Matteo Manfredini
1University of Modena and Reggio Emilia, Department of Chemistry, via Campi 183, 41100 Modena, Italy.
Abstract:
The presence of some essential and toxic metals in fat supplements for swine diet was investigated. Collected samples represented a relevant production of the Italian industry. In particular, some samples were enriched with antioxidants or waste cooking oils. The method for the determination of Ca, Cu, Cd, Fe, Mg, Mn, Ni, Pb, and Zn in fat samples was developed by means of a certified reference material (CRM 186) and a representative fatty sample (RFS). All samples were digested in closed vessels in a microwave oven and then analyzed by flame atomic absorption or graphite furnace atomic absorption spectrometry. The entire analytical method provided a satisfactory repeatability and reproducibility confirmed by agreement between the experimental recovery data obtained for the CRM 186 sample and, with the method of standard additions, for the RFS material. The samples generally showed a small amount of metals compared with the recommended daily intake for the essential elements. On the other hand, some samples contained a significant concentration, from an analytical point of view, of Cd, Ni, and Pb. Principal component analysis (PCA) was applied to inspect the experimental data obtained from samples analysis. Basically no differences were detected in terms of metal concentration among the fat supplements analyzed.
Related Concept Videos
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Fluorescence Spectroscopy

