A multiway approach to overcome the peak resolution challenges in gas-chromatography coupled to ion mobility spectrometry
Related Experiment Video
Updated: Oct 30, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Samuele Pellacani1, Lorenzo Strani1, Daniele Tanzilli2
1Department of Chemical and Geological Sciences, University of Modena and Reggio Emilia, via Campi 103, Modena, 41125, Italy.
Background:
Gas-chromatography coupled to ion mobility spectrometry (GC-IMS) is a powerful platform for untargeted analysis of volatile compounds, combining high sensitivity and short analysis times. However, its practical implementation still presents several analytical and computational challenges. From the instrumental perspective, the high sensitivity of isothermal GC-IMS makes it prone to signal saturation and memory effects, which can compromise the reproducibility of measurements. On the data-analysis side, the nature of GC-IMS outputs produce large and collinear datasets, in which baseline drift, shift in ion mobility and retention time modes, and peak overlap hinder the reliable extraction of relevant chemical information.
Results:
This work proposes a comprehensive workflow from the analytical strategy to the data analysis using as benchmark a data set of honey samples of different origin. Analysing the GC-IMS data, obtained with an instrument operating in isothermal condition, a prominent and marked memory effect was observed; it could be contained only through the systematic use of frequent blanks. Notably, most papers in the literature do not adopt blanks at such frequency. Attention was then devoted to the preprocessing, to improve data quality prior to modelling while limiting the number of preprocessing steps. A multiway approach, i.e. Parallel Factor Analysis 2 (PARAFAC2) applied interval wise, was adopted, for the first time, to resolve overlapping peaks and extract chemically meaningful components from the GC-IMS landscape. The results obtained were also compared with Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) and recent improved PARAFAC2 algorithms.
Significance:
A complete pipeline for the GC-IMS analysis was carefully developed and validated. PARAFAC2, was successfully applied for the deconvolution of GC-IMS data. This approach provided comparable results with previous methods and indicated that the same grade of automation reached in the analysis of GC-MS data with the same approach is feasible.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Analyzers: Overview
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...