Visually estimated left ventricular ejection fraction by echocardiography is closely correlated with formal
Petri Gudmundsson1, Erik Rydberg, Reidar Winter
1Department of Cardiology, Malmö University Hospital, Lund University, Sweden. petri.gudmundsson@skane.se
International Journal of Cardiology
|May 11, 2005
Summary
Eyeballing ejection fraction, a quick visual assessment, strongly correlates with formal echocardiographic methods for evaluating left ventricular systolic function. This suggests it may be a reliable and efficient alternative for routine use.
Area of Science:
- Cardiology
- Medical Imaging
- Echocardiography
Background:
- Established echocardiographic methods for left ventricular systolic function include Simpson ejection fraction, wall motion score index, atrioventricular (AV) plane displacement, and fractional shortening.
- Visually estimated (eyeballing) ejection fraction, while subjective, has shown good correlation with radionuclide ventriculography.
Purpose of the Study:
- To compare the accuracy of echocardiographic eyeballing ejection fraction with established formal methods for assessing left ventricular systolic function.
Main Methods:
- 89 patients post-myocardial infarction or pre-coronary angiography were assessed.
- Eyeballing ejection fraction and wall motion score index were evaluated across multiple views.
- Formal methods (Simpson ejection fraction, AV plane displacement, fractional shortening) were measured from specific views.
Main Results:
- All formal methods showed significant correlation with eyeballing ejection fraction (p<0.001).
- Correlation coefficients ranged from R=0.647 (AV plane displacement) to R=0.898 (biplane Simpson ejection fraction).
- Wall motion score index demonstrated the highest correlation (R=0.919) with eyeballing ejection fraction.
Conclusions:
- Eyeballing ejection fraction closely correlates with all formal echocardiographic assessments of left ventricular systolic function.
- The accuracy of eyeballing ejection fraction appears to improve with the reliability of the formal method used for comparison.
- Eyeballing ejection fraction is a potentially accurate, quick, and readily available method suitable for routine echocardiography.