Related Experiment Video
Updated: Aug 18, 2026

Modeling Brain Metastases Through Intracranial Injection and Magnetic Resonance Imaging
Published on: June 7, 2020
Is brain SPECT a suitable modality for evaluation of postradiotherapy posterior fossa brain tumours? A comparative
Sukanta Barai1, G P Bandopadhayaya, K Naik
1Department of Nuclear Medicine, AIIMS, New Delhi 110029.
Abstract:
Single photon emission computed tomography (SPECT) of the brain is exquisitely sensitive in detecting viable tumour tissue in the supratentorial region, but its efficacy has not been properly evaluated till date in case of infratentorial posterior fossa tumours. Twenty-four patients with primary posterior fossa brain tumour were included in this study. In each case brain SPECT with 99mTc-glucoheptonate (GHA) was performed for the evaluation of disease status. Contrast enhanced computerised tomography of brain was also performed in all the patients. Brain SPECT was positive in four patients with recurrence of tumour as compared to fifteen cases with computed tomography with a mean GHA retention index 5.26 +/- 1.64. Patients with postradiation gliosis (n=9) showed lower GHA retention index of 1.24 +/- 0.27. This study demonstrates that brain SPECT is not sensitive in detecting recurrence of tumour tissue in infratentorial region, as it is in the supratentorial region, with a sensitivity of 20%, accuracy of 45.83% and negative predictive value of 40% and the chance of any single study coming as false negative is about 80%.
Related Concept Videos
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...