Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states
S Scolletta1, S M Romano, B Biagioli
1Department of Surgery and Bioengineering, Thoracic and Cardiovascular Unit, University of Siena, Siena, Italy. scolletta@unisi.it
Background:
Cardiac output (CO) can be measured using the pressure recording analytical method (PRAM), which is a new, less invasive technique allowing beat-by-beat stroke volume monitoring from the pressure signals recorded in femoral or radial arteries.
Methods:
We investigated PRAM by comparing its cardiac output (PRAM-CO) with paired measurements obtained by electromagnetic flowmetry (EM-CO) and by standard thermodilution (ThD-CO) during various haemodynamic states in a swine model. Nine pigs were monitored with a pulmonary artery catheter and a femoral artery catheter at baseline, in a hyperdynamic state produced by administration of dobutamine and in a hypodynamic state induced by progressive exsanguination. Bland-Altman analysis was used.
Results:
One hundred and eight paired cardiac output values over a range of EM-CO of 1.8-10.4 litre min(-1) resulted. We found close agreement between the techniques. Mean bias between EM-CO and PRAM-CO was -0.03 litre min(-1) (precision 0.58 litre min(-1)). The 95% limits of agreement were -0.61 to +0.55 litre min(-1). Similar results between ThD-CO and PRAM-CO were found.
Conclusions:
In a porcine model we have demonstrated accuracy of PRAM during various haemodynamic states. PRAM is a reliable tool to detect changes in cardiac output in pigs and has ability as a basic research tool.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement