Direct processes in chaotic microwave cavities in the presence of absorption

U Kuhl1, M Martínez-Mares, R A Méndez-Sánchez

  • 1Fachbereich Physik, Philipps-Universität Marburg, Renthof 5, D-35032 Marburg, Germany.

Related Concept Videos

Standing Waves in a Cavity01:28

Standing Waves in a Cavity

A household microwave and lasers are examples of standing electromagnetic waves in a cavity. When two conducting metal plates are placed parallel at the nodal planes, it creates a cavity where standing waves are formed. The cavity between the two planes is analogous to a stretched string held at the points x = 0 and x = L. Here, the distance 'L' between the two planes must be an integer multiple of half of the wavelength. The wavelengths that satisfy this condition are given by:
Atomic Nuclei: Nuclear Relaxation Processes01:23

Atomic Nuclei: Nuclear Relaxation Processes

In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis,  the precessing magnetic moments are randomly oriented around the z-axis. This...
Deactivation Processes: Jablonski Diagram01:25

Deactivation Processes: Jablonski Diagram

Luminescence, the emission of light by a substance that has absorbed energy, is a process that involves the interaction of molecules with light. The energy-level diagram, or Jablonski diagram, is a graphical representation of these interactions, illustrating the various states and transitions a molecule can undergo. In a typical Jablonski diagram, the lowest horizontal line represents the ground-state energy of the molecule, which is usually a singlet state. This state represents the energies...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...