Uncertainty analysis of a dynamic vapor sorption-fast gas chromatography-flame ionization detection method for the
Dawn M Bohn1, Arthur R Schmidt, Shelly J Schmidt
1Diageo Global Supply, 903 West 143rd Street, Plainfield, Illinois 60544, USA.
Abstract:
Uncertainty analysis was conducted with a dynamic vapor sorption-fast gas chromatography-flame ionization detection (DVS-fast GC-FID) method, developed to rapidly analyze the extent of volatile release that occurs from carbohydrate glasses due to humidification and temperature increases. Triplicate samples progressed through a two-step special automatic operation method in the DVS. Samples were exposed to relative humidities ranging from 40 to 90% (in 10% increments) at 15, 25, and 35 degrees C. Uncertainty analysis shows that the DVS-fast GC-FID method uncertainty is smaller than the natural sample uncertainty, indicating that the variability in a sample's physical properties has a dominant impact on the overall uncertainty of the volatile retention results obtained using the DVS-fast GC-FID method. Uncertainty analysis also indicates that the variance associated with the mass of benzaldehyde measured by the DVS-fast GC-FID is the largest contributor to the overall benzaldehyde retention variance when the cumulative mass of benzaldehyde measured is small.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Volatilization
Gas Chromatography: Types of Detectors-II
Flame Photometry: Lab
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...