Related Experiment Video
Updated: Aug 17, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Quantitative determination of volatile organic compounds in indoor dust using gas chromatography-UV spectrometry
Anders Nilsson1, Verner Lagesson, Carl-Gustaf Bornehag
1Department of Molecular and Clinical Medicine, Division of Occupational and Environmental Medicine, Linköping University, S-581 83 Linköping, Sweden. AndersENilsson@gmail.com
Abstract:
A novel technique, gas chromatography-UV spectrometry (GC-UV), was used to quantify volatile organic compounds (VOCs) in settled dust from 389 residences in Sweden. The dust samples were thermally desorbed in an inert atmosphere and evaporated compounds were concentrated by solid phase micro extraction and separated by capillary GC. Eluting compounds were then detected, identified, and quantified using a diode array UV spectrophotometer. Altogether, 28 compounds were quantified in each sample; 24 of these were found in more than 50% of the samples. The compounds found in highest concentrations were saturated aldehydes (C5-C10), furfuryl alcohol, 2,6-di-tert-butyl-4-methylphenol (BHT), 2-furaldehyde, and benzaldehyde. Alkenals were also found, notably 2-butenal (crotonaldehyde), 2-methyl-propenal (methacrolein), hexenal, heptenal, octenal, and nonenal. The concentrations of each of the 28 compounds ranged between two to three orders of magnitude, or even more. These results demonstrate the presence of a number of VOCs in indoor dust, and provide, for the first time, a quantitative determination of these compounds in a larger number of dust samples from residents. The findings also illustrate the potential use of GC-UV for analysing volatile compounds in indoor dust, some of which are potential irritants (to the skin, eyes or respiratory system) if present at higher concentrations. The potential use of GC-UV for improving survey and control of the human exposure to particle-bound irritants and other chemicals is inferred.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
UV–Vis Spectrometers
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...