Related Experiment Video
Updated: Aug 17, 2026

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
[Study on the validation of the computer science application's activity monitor in assessing the physical activity
Ai-ling Liu1, Yan-ping Li, Jun Song
1Institute of Nutrition and Food Safety, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
Objective:
Using doubly labeled water method to validate the colmputer science application's activity monitor (CSA) in assessing physical activity of free-living adults in Beijing, in order to develop equations to predict total daily energy expenditure (TEE) and activity related energy expenditure (AEE) from activity counts (AC) and anthropometric variables.
Methods:
A total of 72 healthy adults (33 males and 39 females, mean age 43.6 +/- 4.0 yr) were monitored for 7 consecutive days by CSA. TEE was simultaneously measured using doubly labeled water method. Average AC (counts/min(-1)) was compared with TEE, AEE and physical activity level (PAL).
Results:
Physical activity determined by AC was significantly related to data on energy expenditures: TEE (r = 0.31, P < 0.01), AEE (r = 0.30, P < 0.05), and PAL (r = 0.26, P < 0.05). Multiple stepwise regression analysis showed that TEE was significantly influenced by gender, fat-free mass (FFM) or BMI and AC (R(2) = 0.52 - 0.70) while AEE was significantly influenced by gender, FFM and AC (R(2) = 0.25 - 0.32).
Conclusion:
AC from CSA activity monitor seemed a useful measure in studying the total amount of physical activity in free-living adults while AC significantly contributed to the explained variation in TEE and AEE.