Related Experiment Video
Updated: Aug 17, 2026

2D-HELS MS Seq: A General LC-MS-Based Method for Direct and de novo Sequencing of RNA Mixtures with Different Nucleotide Modifications
Published on: July 10, 2020
Comparison of A+T-rich oligonucleotides with and without self-complementary sequence using ion-pair reversed-phase
Renfang Song1, Wenbing Zhang, Huayong Chen
1State Key Laboratory of Organic Geochemistry, Guangzhou Research Center of Mass Spectrometry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640, China.
Abstract:
Both A+T-rich oligonucleotides with and without self-complementary sequences were analyzed using ion- pair reversed-phase liquid chromatography/electrospray ionization mass spectrometry (IP-RP-HPLC/ESI-MS) by tryethylammonium acetate (TEAA) and hexafluoroisopropanol (HFIP) buffer systems to study the characteristics of their retention behavior and electrospray ionization tandem mass spectrometry (ESI-MS/MS) response. The results indicated that the chain length had the same effect on the retention of A+T-rich oligonucleotides in both of TEAA and HFIP buffer systems but the sequence had a different impact on the retention in the two buffer systems. A+T- rich oligonucleotides with a self-complementary sequence were much shorter than those without in the TEAA buffer system whereas a slight difference was observed in the HFIP buffer system. Similar total ion current (TIC) intensity was observed both in oligonucleotides with or without self-complementary sequence. The opposite trend of a change in the TIC intensities with increasing chain length were observed in both the TEAA and HFIP buffer systems. A lower charge state was predominant in the TEAA buffer system whereas a higher charge state was mainly distributed in the HFIP buffer system. The oligonucleotides without self-complementary sequences had a higher charge state than those with self-complementary sequences. A- and T- are more esily formed at a higher charge state whereas the sequence fragments will be formed more easily at a lower charge state in both A+T-rich oligonucleotides with and without self-complementary sequences.
More Related Videos
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
High-Resolution Mass Spectrometry (HRMS)