Related Experiment Video
Updated: Aug 17, 2026

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
Evaluation of the depth-ratio and backscattering-factor methods in quality control measurements of electron beam
Cleber N De Souza1, Cláudio H Sibata, Linda V E Caldas
1Instituto de Pesquisas Energéticas e Nucleares, Comissão Nacional de Energia Nuclear, Caixa Postal 11049, CEP 05422-970 São Paulo, SP, Brazil.
Abstract:
Sensitivities of two different methods for evaluating electron beam energy have been investigated. One of them uses the ratio of ionization at two depths corresponding to two different points on the depth curve of ionization. The other one uses the magnitude of backscattering by lead as a measure of the electron beam energy. The depth-ratio method was found to be sensitive and practical for a routine quality control program. The sensitivity of the backscattering effect was found to be insufficient for electron energies higher than 12 MeV.