Background:
Previous attempts to measure otolith function using ocular counter-rolling have shown poor sensitivity and specificity, thereby hindering a useful clinical application. We have conducted a study to investigate whether thresholds for the perception of the direction of linear acceleration might be an alternative for the clinical evaluation of otolith or statolith function.
Methods:
Perception of the direction of motion was evaluated in 28 healthy subjects while all external auditory and visual cues were eliminated. Whole body motion stimulus was generated by a motor driven linear sled at a stimulus frequency of 1 Hz at a linear acceleration ranging from 0 to maximum 40 cm/s2. Subjects were required to correctly indicate the direction of motion (anterior-posterior or lateral) or whether they were stationary. Both velocity and acceleration thresholds were measured.
Results:
The median acceleration thresholds for the perception of direction of linear movement for anterior-posterior movement was 8.5 cm/s2 and for lateral movement 6.5 cm/s2. According to the literature, acceleration thresholds depend on the stimulus profile whereas velocity thresholds do not. The median velocity thresholds for the perception of direction of linear movement for anterior-posterior movement was 13.5 cm/s and for lateral movement was 10.4 cm/s. The median velocity thresholds for the perception of direction of linear movement for anterior-posterior movement increased linearly with age, whereas the median velocity threshold for lateral movement was not correlated with age.
Conclusion:
The thresholds found in this study are lower than reported in the literature before which may be due to the repetitive predictive sinusoidal stimulus which makes it relatively easy to lower the threshold by learning already within one test profile. The variability is large in line with the previous literature, but our experiments indicate that variability decreases after a training session. We interpret the literature and our current results that linear velocity thresholds after some training might reflect the sensitivity of the otolith system per se.
Related Concept Videos
The Vestibular System
Equilibrium and Balance
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Relative Motion Analysis - Acceleration
Direction of Acceleration Vectors