Related Experiment Video
Updated: Aug 9, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
[Continuous Fick cardiac output measurement during inhalation anesthesia]
1Department of Anesthesiology, Hokkaido University School of Medicine, Sapporo, Japan.
Abstract:
A computer based system that continuously monitors cardiac output (CO) and the other hemodynamic variables has been developed. Fick CO was calculated every 10 sec on breath by breath basis. The arterio-venous oxygen content difference was measured by a combination of a pulse oximeter and a fiberoptic oximeter. Oxygen consumption was calculated by a direct measurement of respiratory gas exchange: airway flow was obtained from a Servo 900C ventilator and the instantaneous oxygen concentration was measured with a paramagnetic oxygen sensor. This system enabled us to use inhalation anesthetics which were avoided during Fick CO measurement with a zirconium oxygen sensor. Fick CO was compared to electromagnetic CO (EMCO) in 5 dogs anesthetized with enflurane. A total of 198 simultaneous data of CO measurements had a range from 0.5 to 2 l/min. Simultaneous measurements of Fick CO and EMCO showed a good correlation (r = 0.97), and a regression equation was: Y = X + 0.029. Fick CO was compared with cardiac output measured by a conventional thermodilution method (TDCO) in 12 patients anesthetized with either enflurane or isoflurane. A total of 207 simultaneous CO measurements ranged from 3 to 10.2 l/min. Regression analysis of 207 paired Fick CO and TDCO values showed a good correlation (r = 0.94), and a regression equation (Fick CO = TDCO-0.28). The "limits of agreement" (mean difference +/- 2 SD of bias) were within +/- 1.12 l/min, which could be acceptable for clinical settings. When hemodynamic states were abruptly changed by an intravenous administration of isoproterenol, Fick CO reached 90% of EMCO change within 30 sec. The author concludes that this system provides virtually continuous hemodynamic analyses and facilitates more sophisticated circulatory control of the patients within a limited fluctuation.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Cardiopulmonary Resuscitation II: ACLS Airway Management

