Digital mammography using iodine-based contrast media: initial clinical experience with dynamic contrast medium
Felix Diekmann1, Susanne Diekmann, Fanny Jeunehomme
1University Hospital Charité, Berlin, Germany. felix.diekmann@ charite.de
Purpose:
We sought to evaluate the potential of dynamic contrast enhancement after the intravenous administration of an iodine-based contrast medium in full-field digital mammography.
Material And Methods:
A protocol for image acquisition was established for contrast-enhanced mammography and the mammography unit (Senographe 2000D, GE Healthcare, Buc, France) changed as required. The effect of the protocol parameters on imaging was investigated. Subsequently, 21 patients with 25 suspicious lesions of the breast (10 benign, 1 borderline, and 14 malignant) underwent mammography with administration of an iodine-based contrast medium (Ultravist 370, Schering AG, Berlin, Germany), after approval of ethical committee as well as permission of German federal office for Radiation protection, and informed consent from each patient was obtained. Three sequential digital mammographic images of the respective breast were acquired after administration of the contrast medium at a dose of 1 mL/kg body weight and a flow of 4 mL/s. The postcontrast images were acquired 60, 120, and 180 seconds after administration. Subsequently, the precontrast image was logarithmically subtracted from the postcontrast images. Enhancement of the lesions was measured in absolute terms as well as relative to the enhancement of the glandular tissue. The subtracted images were evaluated for lesion depiction and dynamic contrast enhancement. Lesion-enhancement kinetics were compared with the histologic findings.
Results:
All malignant lesions were identified on the contrast-enhanced images of digital mammography. Three of the tumors (2 malignant, 1 benign) were detected only by contrast-enhanced mammography and not by standard mammography. Dynamic enhancement curves of benign and malignant tumors in contrast-enhanced mammography look similar to the curves known from gadolinium-enhanced magnetic resonance imaging. Nevertheless differentiation between malignant and benign tumors based on the enhancement patterns cannot be directly taken over from magnetic resonance imaging, as suggested by our initial results. The results are somewhat better when tumor enhancement relative to surrounding glandular tissue is used instead of absolute enhancement.
Conclusion:
The results of this preliminary study suggest that contrast-enhanced digital mammography is a potentially useful tool for the detection and the differentiation of benign and malignant breast lesions.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI