Bond strength of a mild self-etch adhesive with and without prior acid-etching
K L Van Landuyt1, P Kanumilli, J De Munck
1Leuven BIOMAT Research Cluster, Department of Conservative Dentistry, School of Dentistry, Oral Pathology and Maxillo-Facial Surgery, Catholic University of Leuven, Kapucijnenvoer 7, B-3000 Leuven, Belgium.
Unlabelled:
The self-etch approach provides dentists with a generation of user-friendly and less technique-sensitive adhesives. Nevertheless, some concern has been raised regarding their bonding effectiveness to enamel, in particular when so-called 'mild' self-etch adhesives are employed.
Objectives:
The purpose of this study was to test the hypothesis that the two-step self-etch adhesive Clearfil SE Bond (C-SE; Kuraray, Osaka, Japan) bonds equally effective to enamel/dentin either with or without prior etching with phosphoric acid.
Methods:
Bur-cut enamel/dentin surfaces prepared from human molars were partially split in two halves by cutting a shallow groove. One half was first etched with 40% phosphoric acid (K-etchant), while protecting the other half by holding a razor blade in the groove. Next, C-SE was applied strictly following the manufacturer's instructions, after which the surface was built up using Z100 (3M Espe). After 24-h water storage, micro-specimens were prepared with the interface circularly constricted using a Micro-Specimen Former, prior to micro-tensile bond strength (MPa) measurement. In addition, interfaces of C-SE with enamel/dentin prepared with and without beforehand acid etching were examined by Feg-SEM and TEM.
Results:
Beforehand etching significantly increased the bonding effectiveness of C-SE to enamel. A clearly more micro-retentive surface was revealed by TEM and Feg-SEM when enamel was etched. Phosphoric-acid etching prior to C-SE application on dentin significantly decreased the muTBS to dentin. TEM provided indications of a low-quality hybrid layer after beforehand phosphoric-acid etching.
Conclusion:
Using C-SE, additional etching with phosphoric acid to improve bonding effectiveness should be limited to enamel.
Related Concept Videos
Bonding and Strength of Aggregate
Titration of a Weak Acid with a Strong Base
Titration of a Weak Acid with a Weak Base
As a result, there is no simple...
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Leveling Effect
Conductometric Titrations: Strong Acid-Weak Base and Weak Acid-Strong Base Titrations