Related Experiment Video
Updated: Aug 17, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Simultaneous analysis of termiticides in indoor air by using gas chromatography mass spectrometry
Kiyomi Tsuji1, Yuichi Fushiwaki, Yasuaki Mori
1Chemistry Division, Kanagawa Prefectural Institute of Public Health, Shimomachiya, Chigasaki, Kanagawa 253-8523, Japan.
Abstract:
We have established a method for simultaneously analyzing termiticides (13 kinds) in indoor air based on collection by combination of quartz filter and C18 Empore extraction disks, and measurement using gas chromatography mass spectrometry (GC/MS). The lower limit of determination for each substance was 0.02 microg/m3 when 2 m3 of air was sampled. The recovery was 66-100%, and the relative standard deviation was 3.7-14.2%. In experiments using a model box with commercial termiticides, we verified that emissions of bis (2, 3, 3, 3-tetrachloropropyl) ether (S421) increased with a rise in temperature from 10 degrees C to 20 degrees C to 40 degrees C, whereas almost no etofenprox was released into the air regardless of temperature. In addition, decanal, nonanal and alkanes (C13 and C14), which are major components of termiticides, were detected in relatively high concentrations. In the present study, regardless of low vapor pressure of the termiticides, several compounds were detected with the model box experiment. The conclusion that can be drawn is that it is necessary to survey the indoor environmental pollution.
More Related Videos
05:20Determination of 45 Pesticides in Avocado Varieties by the QuEChERS Method and Gas Chromatography-Tandem Mass Spectrometry
Published on: December 8, 2023
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...