Related Experiment Video
Updated: Aug 16, 2026

Fabrication of Extracellular Matrix-derived Foams and Microcarriers as Tissue-specific Cell Culture and Delivery Platforms
Published on: April 11, 2017
Aerosol delivery of mammalian cells for tissue engineering
Andrew Roberts1, Barbara E Wyslouzil, Lawrence Bonassar
1Department of Chemical Engineering, Worcester Polytechnic Institute, Worcester, Massachusetts 01609-2280, USA.
Abstract:
We developed a two fluid atomizer to spray mammalian cells suspended in phosphate buffered saline (PBS)-Pluronic F-127 polymer solutions. We used the device to spray suspensions of bovine articular chondrocytes and porcine tracheal epithelial cells, in either PBS or the polymer solutions, and studied their viability and growth kinetics. Under the operating conditions examined in this study, the cells had better than 70% viability after spraying, the growth rates were comparable to cells that were not sprayed, and the appearance of the cells at confluence was normal.