Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Measuring blood pressure in small laboratory animals
1Department of Safety and Environmental Affairs (DVM), Free University, Amsterdam, The Netherlands.
Abstract:
The most common techniques currently employed for monitoring blood pressure (BP) in conscious rats and mice are the tail cuff and the exteriorized catheter that feeds a pressure transducer located outside the cage. There are, however, considerable drawbacks associated with these methods, which in many respects make each of these techniques undesirable as an accurate means of obtaining pressure measurements. Recent studies have shown that measurements of physiological variables, such as electrocardiogram (ECG), heart rate (HR), and body temperature (BT), from freely moving rats and mice by using implantable radiotelemetry were more efficient, reliable and less labour intensive when compared to measurement techniques described in the literature so far. Nowadays, measurement of BP by radiotelemetry has been described and validated for many laboratory animal species, including rats and mice. The implantable radiotelemetry technique can circumvent many of the problems associated with conventional methods (tail cuff; exteriorized catheters) of BP monitoring in mice and rats. This chapter describes the surgical aspects of the radiotelemetry techniques currently used to monitor and measure blood pressure in awake animals.
Related Concept Videos
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.