Narcotrend or bispectral index monitoring during desflurane-remifentanil anesthesia: a comparison with a standard
Sascha Kreuer1, Jörgen Bruhn, Christian Stracke
1Department of Anesthesiology and Intensive Care Medicine, *University of Saarland, Homburg/Saar; †University of Bonn, Bonn; and ‡St.-Marien-Hospital, Lünen, Germany.
Unlabelled:
Bispectral Index (BIS) (Aspect Medical Systems, Newton, MA) and Narcotrend (MonitorTechnik, Bad Bramstedt, Germany) are monitoring devices that were, as others, designed to assess the depth of anesthesia. Meanwhile, a number of studies indicate that with total IV anesthesia, BIS and Narcotrend have comparable effects on drug consumption and recovery times whereas comparative clinical data for volatile anesthetics are still missing. Therefore, we designed the present prospective, randomized, and double-blinded study to compare the effects of BIS and Narcotrend monitoring during desflurane-remifentanil anesthesia and versus a standard anesthetic practice protocol. One-hundred-twenty adult patients scheduled for minor orthopedic surgery were randomized to receive a desflurane-remifentanil anesthetic controlled either by Narcotrend or by BIS or solely by clinical variables. Anesthesia was induced with 0.4 microg x kg(-1) x min(-1) remifentanil and 2 mg/kg propofol. After tracheal intubation, remifentanil was infused at a constant rate of 0.2 microg x kg(-1) x min(-1) whereas desflurane in 1.5 L/min O(2)/air was adjusted according to clinical variables or the following target values: during maintenance of anesthesia to a value of "D(0)" (Narcotrend) or "50" (BIS), 15 min before the end of surgery to "C(1)" (Narcotrend) or "60" (BIS), whereas in the standard protocol group, desflurane was controlled according to clinical variables, e.g., heart rate, arterial blood pressure, movements. Recovery times and desflurane consumption were recorded by a blinded investigator. The desflurane vaporizer was weighed before and after anesthesia and consumption per minute was calculated. Data are mean +/- sd. The groups were comparable for demographic data, duration of anesthesia, and mean remifentanil dosages. Compared with standard practice, patients with Narcotrend or BIS monitoring needed significantly less desflurane (standard practice 443 +/- 71 mg/min, Narcotrend 374 +/- 124 mg/min, BIS monitoring 416 +/- 99 mg/min desflurane [both P < 0.05]). However, recovery times were not significantly different between the groups, e.g., opening of eyes 4.7 +/- 2.2 versus 3.7 +/- 2.0 versus 4.2 +/- 2.1 min. During desflurane-remifentanil anesthesia, Narcotrend and BIS monitoring seem to be equally effective compared with standard anesthetic practice: BIS and Narcotrend allow for a small reduction of desflurane consumption whereas recovery times are only slightly reduced.
Implications:
Monitoring the electroencephalogram with Narcotrend or Bispectral Index during desflurane-remifentanil anesthesia only slightly reduces recovery times when compared with a standard practice protocol.
More Related Videos
07:54Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Related Concept Videos
Inhalational Anesthetics: Overview
Parenteral Anesthetics: Overview
Stages of General Anesthesia