Are conventional pressure-flow measurements dependent upon filled volume?

Kanagasabai Sahadevan1, Ann S Leonard, Robert S Pickard

  • 1Department of Urology, Freeman Hospital, Newcastle upon Tyne, UK.

BJU International
|July 27, 2005
PubMed
Abstract

Related Concept Videos

Pipe Flowrate Measurement01:28

Pipe Flowrate Measurement

In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
Measurement of Fluid Pressure01:16

Measurement of Fluid Pressure

Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Pressure Variation in a Fluid at Rest01:11

Pressure Variation in a Fluid at Rest

In a fluid at rest, the pressure at any point beneath the fluid surface depends solely on the depth, not on the container's shape or size. This principle, known as hydrostatic pressure, arises because, in stationary fluids, there is no acceleration, meaning the forces within the fluid balance out. Only vertical forces, caused by the weight of the fluid above, contribute to pressure changes with depth.
When measuring pressure at two different levels within the fluid, the difference in pressure...
Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
Bernoulli's Equation: Problem Solving01:16

Bernoulli's Equation: Problem Solving

A Venturi meter is essential for measuring fluid flow rates in pipelines. It utilizes the relationship between fluid velocity and pressure described by Bernoulli's equation. When installed in a sewage system, the Venturi meter accurately determines the wastewater flow rate by measuring pressure differences.
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
Conservation of Mass in Fixed, Nondeforming Control Volume01:07

Conservation of Mass in Fixed, Nondeforming Control Volume

The principle of conservation of mass is fundamental in fluid dynamics and is crucial for analyzing flow within fixed control volumes, such as pipes or ducts. This principle states that the total mass within a control volume remains constant unless altered by the inflow or outflow of mass through the control surfaces. This results in a vital relationship for steady, incompressible flow where the mass entering a system equals the mass leaving it.
In the case of a sewer pipe, which can be modeled...