Related Experiment Video
Updated: Aug 16, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Optimized condition for etching fused-silica phase gratings with inductively coupled plasma technology
Shunquan Wang1, Changhe Zhou, Huayi Ru
1Shanghai Institute of Optics and Fine Mechanics, Academia Sinica, China.
Abstract:
Polymer deposition is a serious problem associated with the etching of fused silica by use of inductively coupled plasma (ICP) technology, and it usually prevents further etching. We report an optimized etching condition under which no polymer deposition will occur for etching fused silica with ICP technology. Under the optimized etching condition, surfaces of the fabricated fused silica gratings are smooth and clean. Etch rate of fused silica is relatively high, and it demonstrates a linear relation between etched depth and working time. Results of the diffraction of gratings fabricated under the optimized etching condition match theoretical results well.