[Estimation of X-radiation protective coats in abdominal angiography]
Kichiro Koshida1, Takumi Sota, Kimiya Noto
1Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Kanazawa University.
Abstract:
Medical personnel involved in abdominal angiography are exposed not only to direct radiation but also scattered radiation from inspection tables, patients, image intensifiers, and the beam-limiting system (collimator), among others. Japanese standard JISZ4831 prescribes protective coats of at least 0.25 mm lead equivalent, which is the uniform thickness of lead equivalent. The most commonly used protective coats are 0.25 mm Pb, 0.35 mm Pb, or 0.5 mm Pb in thickness. The weight of a typical protective coat is about 3 kg. While some coats weigh up to 6 kg, wearing such heavy coats becomes physically burdensome as inspection time increases. The trade-off between physical burden and protection was considered by analyzing the X-ray intensity distribution and attenuation rate of scattered radiation in each position assumed by the medical staff. In the case of inspections performed at an x-ray tube voltage of 80 kV, it may be possible to reduce the weight of the lead rubber apron by about 33%. Namely, the lead thickness can be reduced uniformly by 0.20 mm Pb at 70 cm and 0.05 mm Pb at 100 cm, when the shielding capability of a 0.25 mm thick Pb layer is accepted as the standard at 40 cm above the gonad position. The same range of permeated X-ray dose for the gonad position may be reduced as well. In the case of 110 kV, when the lead thicknesses are 0.30 mm Pb at 40 cm and 70 cm, and 0.10 mm Pb at 100 cm, it is possible to reduce the weight of the lead rubber apron by about 28%.
Related Concept Videos
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT