Related Experiment Video
Updated: Aug 16, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Percent right ventricular pacing predicts outcomes in the DAVID trial
Arjun D Sharma1, Carlos Rizo-Patron, Alfred P Hallstrom
1Regional Cardiology Associates, Sacramento, California 95819, USA. asharma@rcamd.com
Background:
The Dual-Chamber and VVI Implantable Defibrillator (DAVID) trial demonstrated a worse outcome in patients with implantable cardioverter-defibrillators (ICDs) programmed to DDDR at 70 bpm compared with patients who had ICDs programmed to VVI backup pacing at 40 bpm. Pacing was more frequent in the DDDR group.
Objectives:
The purpose of this study was to determine whether right ventricular pacing (RV) is an independent predictor of outcome in the DAVID trial.
Methods:
We evaluated the relationship of percent RV pacing to the composite endpoint of death or hospitalization for congestive heart failure. Patients who had a 3-month follow-up and who had not yet reached an endpoint were included in the study. Using Cox regression analysis (VVI group N = 195; DDDR group N = 185), we examined multiple factors, including percent RV pacing at 3-month follow-up, that might be associated with adverse outcomes.
Results:
Percent RV pacing as a continuous variable was correlated with the primary endpoint. As a dichotomous variable, the best separation for predicting endpoints occurred with DDDR RV pacing > 40% vs DDDR RV pacing < or = 40% (P = .025). Patients with DDDR RV pacing < or = 40% had similar or better outcomes to the VVI backup group (P = .07). Correction for baseline variables predictive of the composite outcome in the (nonpaced) VVI group (use of nitrates, increased heart rate, and increased age) did not change the findings for RV pacing (P = .008). In contrast, atrial pacing was not predictive of worse outcomes.
Conclusion:
These results suggest, but do not prove, a causal relationship between frequent RV pacing and adverse outcomes in patients with left ventricular ejection fraction < or = 40%.
More Related Videos
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Heart Failure IV: Classification and Diagnostic Evaluation
Cardiomyopathy V: Interprofessional Care
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...