Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
Published on: August 16, 2012
Investigating the enhancement of three-dimensional diffraction tomography by using multiple illumination planes
Angelos T Vouldis1, Costas N Kechribaris, Theofanis A Maniatis
1Biomedical Simulations and Imaging Laboratory, Department of Electrical and Computer Engineering, National Technical University of Athens, Iroon Polytechniou 9, Zografos 15773, Athens, Greece. avouldis@biosim.ntua.gr
Abstract:
The three dimensional (3-D) extension of the two well-known diffraction tomography algorithms, namely, direct Fourier interpolation (DFI) and filtered backpropagation (FBP), are presented and the problem of the data needed for a full 3-D reconstruction is investigated. These algorithms can be used efficiently to solve the inverse scattering problem for weak scatterers in the frequency domain under the first-order Born and Rytov approximations. Previous attempts of 3-D reconstruction with plane-wave illumination have used data obtained with the incident direction restricted at the xy plane. However, we show that this restriction results in the omission of the contribution of certain spatial frequencies near the omegaz axis for the final reconstruction. The effect of this omission is studied by comparing the results of reconstruction with and without data obtained from other incident directions that fill the spatial frequency domain. We conclude that the use of data obtained for incident direction in only the xy plane is sufficient to achieve a satisfactory quality of reconstruction for a class of objects presenting smooth variation along the z axis, while abrupt variations along the z axis cannot be imaged. This result should be taken into account in the process of designing the acquisition geometry of a tomography scanner.
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy
Super-resolution Fluorescence Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Three-Dimensional Microscopy in Microbiology