Related Experiment Video
Updated: Jul 14, 2026

08:50
Total Internal Reflection Absorption Spectroscopy (TIRAS) for the Detection of Solvated Electrons at a Plasma-liquid Interface
Published on: January 24, 2018
Is the diffuse interstellar absorption band at 4430 A caused by trivalent iron ?
1Department of Energy, Mines and Resources, Ottawa, Ontario.
Nature
|May 30, 1970
Summary
No abstract available in PubMed .
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Microbes and Other Elemental Cycles
Microbial activity plays a pivotal role in the biogeochemical cycling of iron and manganese, especially at the redox gradients characteristic of stratified aquatic environments. These cycles are driven by microbial transformations between oxidized and reduced forms of the metals, allowing organisms to exploit them for metabolic energy and structural purposes.Iron Cycling Across Redox GradientsIn neutral, oxygen-rich surface waters, iron is predominantly found in its oxidized, insoluble ferric...

