Correlation analysis of stenotic aortic valve flow patterns using phase contrast MRI.

Emily A Waters1, Shelton D Caruthers, Samuel A Wickline

  • 1Cardiovascular MR Laboratories, Cardiovascular Division, Washington University School of Medicine, St. Louis, MO 63110, USA.

Annals of Biomedical Engineering
|August 3, 2005
PubMed
Summary

Phase contrast MRI reliably measures blood flow in aortic stenosis, showing minimal impact from image positioning. This technique is a robust tool for evaluating this valvular pathology.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Biodistribution and Biodegradation of an Osteoinductive Supramolecular Polymer Implant in a Rat Spinal Fusion Model.

Journal of functional biomaterials·2026
Same author

Corrigendum to 'NADPH oxidase 4 regulates vascular inflammation in aging and atherosclerosis' [Journal of Molecular and Cellular Cardiology 102 (2017) 10-21].

Journal of molecular and cellular cardiology·2026
Same author

Nucleic acid-based therapeutics to restore joint homeostasis in age-related and post-traumatic arthritis.

npj biomedical innovations·2026
Same author

Analysis and management of thermal loads generated in vivo by miniaturized optoelectronic implantable devices.

Device·2025
Same author

Augmented expression of superoxide dismutase 2 mitigates progression and rupture of experimental abdominal aortic aneurysm.

Theranostics·2025
Same author

Safety Evaluations of Rapamycin Perfluorocarbon Nanoparticles in Ovarian Tumor-Bearing Mice.

Nanomaterials (Basel, Switzerland)·2024

Area of Science:

  • Cardiovascular Imaging
  • Medical Physics
  • Radiology

Background:

  • Phase contrast MRI (PC-MRI) is a developing technique for assessing valvular heart disease.
  • The influence of imaging plane position and valvular pathology on PC-MRI velocity measurements requires further investigation.

Purpose of the Study:

  • To evaluate the impact of variable image positioning on velocity measurements in aortic stenosis using PC-MRI.
  • To compare velocity maps with image correlation methods for assessing valve orifice area calculations.

Main Methods:

  • Quantitative flow images were acquired using PC-MRI in four parallel planes in patients with aortic stenosis (n=22).
  • Velocity-time integrals (VTIs) were computed, and cross-correlation methods were used to compare flow profiles at different positions.

Related Experiment Videos

  • Analysis focused on supravalvular and subvalvular regions to assess jet alignment and position dependency.
  • Main Results:

    • Supravalvular VTIs showed strong correlation (R=0.96) and comparable values across positions.
    • Subvalvular VTIs demonstrated a linear relationship (R=0.93) with a 23% mean difference.
    • Cross-correlations indicated predominantly concentric jets, with measurements showing relative insensitivity to imaging plane position, especially in the aortic region.

    Conclusions:

    • Phase contrast MRI measurements of aortic stenosis are largely insensitive to imaging plane position.
    • The study confirms PC-MRI as a dependable method for evaluating aortic stenosis.
    • Correlation methods effectively quantify flow profile similarity and alignment in PC-MRI data.