Related Experiment Video
Updated: Aug 16, 2026
![Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F50301.jpg&w=3840&q=50)
Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
Measurement of gastric emptying by octanoate metabolism
Sarah J Jackson1, Leslie J C Bluck
1MRC-Human Nutrition Research, Elsie Widdowson Laboratory, Cambridge, UK. sarah.jackson@mrc-hnr.cam.ac.uk
Purpose Of Review:
Since its introduction just over 10 years ago, there have been a number of studies that have used the octanoate breath test to assess gastric emptying. Although use of the method is on the increase (the number of gastric emptying studies published on PubMed using the octanoate breath test has doubled between the periods 1997-2000 and 2001-2004 compared with a drop of approximately 20% in the use of scintigraphy over the same periods), the methodology has not achieved universal acceptance, primarily because it can provide results comparable to established techniques only indirectly.
Recent Findings:
Recent methods for overcoming this difficulty are reviewed, including modified methods for breath test interpretation and the application of the related saliva test. The latter promises to be useful as a non-invasive proxy for established techniques, such as scintigraphy, for further validation of the breath test. Recent applications of octanoate-based methods are briefly considered.
Summary:
A novel approach detailed in this review for breath test interpretation, where the bicarbonate pool is modelled as a single compartment, could prove useful for obtaining breath test gastric emptying parameters that are directly comparable with those obtained from the gold standard, gamma scintigraphy. In combination with the saliva test, this could add credence to use of the octanoate breath test as a clinically accepted diagnostic tool, in addition to its potential in research.
Related Concept Videos
Gastric Emptying
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Pyloric Obstruction
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
