Simultaneous Data Collection of fMRI and fNIRS Measurements Using a Whole-Head Optode Array and Short-Distance Channels
Published on: October 20, 2023
Heterogeneous oxygen extraction in the visual cortex during activation in mild hypoxic hypoxia revealed by
Pasi I Tuunanen1, Ian J Murray, Neil R A Parry
1Faculty of Life Sciences, The University of Manchester, Manchester, UK.
Abstract:
Functional magnetic resonance imaging (fMRI) techniques were used to study haemodynamic and metabolic responses in human visual cortex during varying arterial blood oxygen saturation levels (Y(sat), determined by pulse-oximeter) and stimulation with contrast-reversing checkerboards. The visual-evoked potential amplitude remained constant at lowered Y(sat) of 0.82+/-0.03. Similarly, fMRI cerebral blood flow (CBF) responses were unchanged during reduced Y(sat). In contrast, visual cortex volume displaying blood oxygen level-dependent (BOLD) fMRI response decreased as a function of Y(sat), but the BOLD signal change of 3.6%+/-1.4% was constant. Oxygen extraction ratio (OER) during visual activation showed values of 0.26+/-0.03 for normal Y(sat). At lowered Y(sat), two OER patterns were observed. Firstly, a reduced OER of 0.14+/-0.03 in the visual cortex structures showing BOLD in hypoxia was observed. Secondly, signs of much higher OER in other parts of visual cortex were obtained. T2*-weighted magnetic resonance imaging revealed signal increases by 0.8%+/-0.4% with visual activation during lowered Y(sat) in the visual cortex structures, which showed BOLD of 3.6% in magnitude under normoxia. Because the CBF response in the visual cortex was quantitatively similar during stimulation in normoxia and hypoxia, attenuated T2*-weighted signal increase in parts of visual cortex indicated high OER during visual activation in hypoxia, which was close to that encountered in the resting brain. These spatially localised regions of tissue oxygen extraction and metabolism argue for dissociation between CBF and BOLD fMRI signals in mild hypoxia. The findings point to heterogeneity with regard to oxygen requirement and its coupling to the haemodynamic response in the brain.
More Related Videos
12:03Detection of Microregional Hypoxia in Mouse Cerebral Cortex by Two-photon Imaging of Endogenous NADH Fluorescence
Published on: February 21, 2012
05:25An Experiment Using Functional Near-Infrared Spectroscopy and Robot-Assisted Multi-Joint Pointing Movements of the Lower Limb
Published on: June 7, 2024