Related Experiment Video
Updated: Aug 16, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
A pilot study of a simple photon migration model for predicting depth of cure in dental composite
Yin-Chu Chen1, Jack L Ferracane, Scott A Prahl
1Department of Biomedical Engineering, OHSU, 9205 SW Barnes Rd., Portland, OR 97225, USA.
Objectives:
The purpose of this study was to build a photo migration model to calculate the radiant exposure (irradiancextime) in dental composite and to relate the radiant exposure with extent of cure using polymer kinetics models.
Methods:
A composite (Z100, Shade A2) cylinder (21 mm diameter by 15 mm deep) was cured with a tungsten-halogen lamp emitting 600 mW/cm2, 1 mm above the composite for 60s. For each of the 2x1 mm grids along the longitudinal cross section (diameter versus depth), the degree of conversion (DC) and hardness (KHN) were measured to construct the curing extent distribution. The inverse adding-doubling method was used to characterize the optical properties of the composite for the Monte Carlo model simulating the photon propagation within the composite cylinder. The calculated radiant exposure (H) distribution along the cross section was related to the curing extent DC/DC(max) distribution and fitted with two polymer curing kinetics models, the exponential model DC=DC(max)[1-exp((ln0.5)H/H(dc)(50%))] and Racz's model [Formula: see text] , where H(dc)(50%) is a fitting parameter representing the threshold for 50% of the maximum curing level.
Results And Significance:
The absorption and scattering coefficients of uncured composite were higher than that of cured composite at wavelengths between 420 and 520 nm. A roughly hemi-spheric distribution of radiant exposure in the Monte Carlo simulation result was comparable with the curing profiles determined by both DC and KHN. The relationship between DC (or KHN) and H agreed with the Racz model (r2=0.95) and the exponential model (r2=0.93). The H(dc)(50%) was 1.5(0.1), equal for the two models (P<0.05). The estimated radiant exposure threshold for 80% of the maximum curing level was between 3.8 and 8.8 J/cm2. The simulation results verify that the radiant exposure extends to a greater depth and width for composite with lower absorption and scattering coefficients. Given the optical properties and the geometry of the composite, and the spectrum and the geometry of the light source, the Monte Carlo simulation can accurately describe the radiant exposure distribution in a composite material to predict the extent of cure.

