One-photon mass-analyzed threshold ionization spectroscopy of 2-chloropropene (2-C3H5Cl) and its vibrational

Yong Jin Bae1, Mina Lee, Myung Soo Kim

  • 1National Creative Research Initiative Center for Control of Reaction Dynamics and School of Chemistry, Seoul National University, Seoul 151-742, Korea.

Related Concept Videos

Mass Spectrometry: Alkyl Halide Fragmentation01:22

Mass Spectrometry: Alkyl Halide Fragmentation

Chlorine isotopes exist as 35Cl and 37Cl in a 3:1 ratio, while bromine isotopes exist as 79Br and 81Br in a 1:1 ratio. The mass spectrum of alkyl halides typically produces two distinct molecular ion peaks, the molecular ion peak, [M], and the molecular ion plus two, [M + 2] peak. The relative heights of these two peaks are proportional to the isotopic abundance ratios of the halide. For example, 2‐chloropropane and 1‐bromopropane display two peaks with relative peak heights in a 3:1 and 1:1...
Inductive Effects on Chemical Shift: Overview01:27

Inductive Effects on Chemical Shift: Overview

The protons in unsubstituted alkanes are strongly shielded with chemical shifts below 1.8 ppm. Methine, methylene, and methyl protons appear at approximately 1.7, 1.2 and 0.7 ppm, while the proton signal from methane appears at 0.23 ppm. An electronegative substituent, such as chlorine, withdraws the electron density from the protons, increasing their chemical shift. Progressive substitution of the hydrogens in methane by chlorine shifts the proton signals increasingly downfield, to 3.05 ppm in...
Mass Spectrum: Interpretation01:24

Mass Spectrum: Interpretation

An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Mass Spectrum01:23

Mass Spectrum

A mass spectrum is the graphical representation of the relative abundance of the charged fragments in an analyte plotted against their mass-to-charge ratio (m/z). The plot's x-axis represents the ratio of the mass of the charged fragment to the number of charges it carries. The y axis of the plot represents the relative abundance of each charged species. The relative abundance is calculated from the signal intensity of each charged species recorded at the detector. The most intense signal (the...
Mass Spectrometry: Cycloalkane Fragmentation01:05

Mass Spectrometry: Cycloalkane Fragmentation

In mass spectrometry, cycloalkanes exhibit distinct fragmentation patterns due to the inherent stability of their molecular ions compared to linear or branched alkanes. The ring structure of cycloalkanes provides additional stability to the molecular ions, often resulting in prominent ion peaks in the mass spectrum.
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...