Updated: Jun 12, 2026

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Peri-implant bone response to orthodontic loading: Part 2. Implant surface geometry and its effect on regional bone
Rodrigo Oyonarte1, Robert M Pilliar, Douglas Deporter
1Orthodontics Program, Faculty of Dentistry, University of Toronto, Toronto, Ontario, Canada.
Introduction:
Bone response to orthodontic loading was compared around 2 different types of osseointegrated implants (porous surfaced and machined threaded) to determine the effect of implant surface geometry on regional bone remodeling.
Methods:
Five beagles each received 3 implants of each design in contralateral mandibular extraction sites. After a 6-week initial healing period, abutments were placed, and, 1 week later, the 2 mesial implants on each side were orthodontically loaded for 22 weeks. All implants remained osseointegrated throughout orthodontic loading except for 1 threaded implant that loosened. Back-scattered scanning electron microscopy and fluorochrome bone labeling techniques were used to compare responses around the 2 types of implants.
Results:
The loaded, porous-surfaced implants had significantly higher marginal bone levels and greater bone-to-implant contact than did the machined-threaded implants.
Conclusions:
Significant differences in peri-implant bone remodeling and bone formation in response to controlled orthodontic loading were observed for the 2 implant designs. Short, porous-surfaced implants might be more effective for orthodontic applications than machine-threaded implants.