Related Experiment Video
Updated: Aug 16, 2026

Image Acquisition using Portable Sonography for Emergency Airway Management
Published on: September 28, 2022
Identification of endotracheal tube malpositions using computerized analysis of breath sounds via electronic
Christopher J O'Connor1, Hansen Mansy, Robert A Balk
1*Department of Anesthesiology, †Department of Pediatrics, ‡Department of Pulmonary Medicine and Critical Care, Rush Medical College at Rush University Medical Center, Chicago, Illinois.
Abstract:
Endotracheal tube (ETT) malpositioning into a mainstem bronchus or the esophagus may result in significant hypoxemia. Current methods to determine correct ETT position include auscultation, radiography, and bronchoscopy, although the current acceptable standard procedure for proper endotracheal (versus esophageal) intubation is detection of end-tidal carbon dioxide (ETco(2)) by capnography, capnometry, or colorimetric ETco(2) devices. Unfortunately, capnography may be unavailable or unreliable in nonhospital/emergency settings or in low cardiac output states, and it does not detect endobronchial intubation. The purpose of this study was to quantify and assess breath sound characteristics using electronic stethoscopes placed over each hemithorax and epigastrium to determine their ability to detect ETT malposition. We recorded breath sounds in 19 healthy, non-obese adults before general surgical procedures. After intubation of the trachea, the ETT was bronchoscopically positioned 3 cm above the carina, after which 3 breaths of 500 mL were given and breath sounds were recorded. A second ETT was placed in the esophagus and the same series of breaths and recordings were performed. Finally, the tracheal ETT was advanced into the right mainstem bronchus and breath sounds were recorded. Using computerized analysis, breath sounds were digitized and filtered to remove selected frequencies, and acoustic signals and energy ratios were obtained for all 3 positions. Total energy ratios using band-pass filtering of the acoustic signals accurately identified all esophageal and endobronchial intubation (P < 0.001). These preliminary results suggest that this technique, when incorporated into a 3-component, electronic stethoscope-type device, may be an accurate, portable mechanism to reliably detect ETT malposition in adults when ETco(2) may be unavailable or unreliable.
Related Concept Videos
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...