How well can anaesthetists discriminate pulse oximeter tones?
1Sydney Medical Simulation Centre, Royal North Shore Hospital and The University of Sydney, New South Wales.
Abstract:
The ability of experienced anaesthetists to discern oxygen saturation by listening to the tones of a Datex AS3 pulse oximeter was examined. Five-second samples were recorded using a high fidelity patient simulator and replayed singly and in pairs. Whilst the lower saturations were generally recognized as lower, the perceived range was greatly compressed. Median perceived estimates for 70% saturation was 89%, for 80% was 93% and for 94% was 94%. When comparing pairs of samples, the direction of the difference was correctly discerned by 70% of anaesthetists for differences of 2%, rising to 95% for differences of greater than 8% oxygen saturation. The magnitude of the difference was consistently underestimated. With an actual difference of 20%, the median estimate was 5%. The results indicate that while qualitative estimate changes in oxygen saturation are moderately reliable, quantitative estimation is severely limited by a compromised perceived scale. This may lead to underestimation of the severity if the auditory signal is relied on in isolation. A non-linear (musical) scale may prove more appropriate and should be investigated. Testing experienced anaesthetists demonstrated that most could detect the direction, but not the magnitude of a change in saturation by listening to the change in pitch of a Datex AS3 pulse oximeter tone.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical indicator...