Dry and moist heat sterilisation cannot inactivate pyrogenicity of Gram positive microorganisms
Lise Moesby1, Erik W Hansen, Jens D Christensen
1The Danish University of Pharmaceutical Sciences, Department of Pharmacology, 2 Universitetsparken, DK-2100 Copenhagen, Denmark. LM@dfuni.dk
Abstract:
In the monocytic cell line Mono Mac 6 pyrogens induce interleukin-6 secretion dose dependently. The aim of this study is to examine the interleukin-6 inducing capacity of Gram positive Staphylococcus aureus and Bacillus subtilis endospores after moist and dry heat sterilisation. Moist heat sterilisation of B. subtilis endospores for 15 min at 121 degrees C and 134 degrees C can only reduce the interleukin-6 inducing capacity to 57% and 63%, respectively, compared to untreated. Moist heat sterilisation of S. aureus for 60 min at 121 degrees C and 134 degrees C does not reduce the interleukin-6 inducing capacity of S. aureus. On the contrary moist heat sterilisation at 134 degrees C for 10, 20 and 40 min significantly increases the interleukin-6 inducing capacity compared to untreated S. aureus. This is confirmed in the rabbit pyrogen test. Dry heat sterilisation of B. subtilis endospores at 220 degrees C for 45 min reduces the interleukin-6 inducing capacity to 2% compared to untreated endospores. Dry heat treatment of S. aureus at 220 degrees C for 30 min only reduces the activity to 55%. However, after 250 degrees C for 30 min or 220 degrees C for 6h there is no detectable activity of S. aureus. In conclusion, neither the interleukin-6 inducing activity nor the pyrogenicity of S. aureus and endospores of B. subtilis can be inactivated by the heat sterilisation procedures described by the European Pharmacopoeia.
More Related Videos
10:03Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy
Published on: November 30, 2017
05:45Process Development for the Spray-Drying of Probiotic Bacteria and Evaluation of the Product Quality
Published on: April 7, 2023
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Key Techniques in Microbiology
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Pasteurization and Food Preservation