Related Experiment Video
Updated: Aug 16, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Effects of alveolar dead-space, shunt and V/Q distribution on respiratory dead-space measurements
Y Tang1, M J Turner, A B Baker
1Department of Anaesthetics, University of Sydney, Royal Prince Alfred Hospital, NSW, Australia.
Background:
Respiratory dead-space is often increased in lung disease. This study evaluates the effects of increased alveolar dead-space (Vd(alv)), pulmonary shunt, and abnormal ventilation perfusion ratio (/) distributions on dead-space and alveolar partial pressure of carbon dioxide (Pa(co(2))) calculated by various methods, assesses a recently published non-invasive method (Koulouris method) for the measurement of Bohr dead-space, and evaluates an equation for calculating physiological dead-space (Vd(phys)) in the presence of pulmonary shunt.
Methods:
Pulmonary shunt, / distribution and Vd(alv) were varied in a tidally breathing cardiorespiratory model. Respiratory data generated by the model were analysed to calculate dead-spaces by the Fowler, Bohr, Bohr-Enghoff and Koulouris methods. Pa(co(2)) was calculated by the method of Koulouris.
Results:
When Vd(alv) is increased, Vd(phys) can be recovered by the Bohr and Bohr-Enghoff equations, but not by the Koulouris method. Shunt increases the calculated Bohr-Enghoff dead-space, but does not affect Fowler, Bohr or Koulouris dead-spaces, or Vd(phys) estimated by the shunt-corrected equation if pulmonary artery catheterization is available. Bohr-Enghoff but not Koulouris or Fowler dead-space increases with increasing severity of / maldistribution. When alveolar Pco(2) is increased by any mechanism, Pa(co(2)) calculated by Koulouris' method does not agree well with average alveolar Pco(2).
Conclusions:
Our studies show that increased pulmonary shunt causes an apparent increase in Vd(phys), and that abnormal / distributions affect the calculated Vd(phys) and Vd(alv), but not Fowler dead-space. Dead-space and Pa(co(2)) calculated by the Koulouris method do not represent true Bohr dead-space and Pa(co(2)) respectively, but the shunt-corrected equation performs well.
More Related Videos
Related Concept Videos
Respiratory Volumes and Capacities
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
External and Internal Respiration
Atelectasis II: Pathophysiology
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...