Related Experiment Videos
Rapid isolation of human complement component C9 to verify the specificity of a haemolytic C9 microassay
H J Bootsma1, C W van den Berg, H van Dijk
1Eijkman-Winkler Laboratory of Medical Microbiology, University Hospital, Utrecht, Netherlands.
Abstract:
A sensitive, haemolytic microassay of human complement component C9 was developed. The assay is based on the principle of reactive (C5b6-initiated) haemolysis and uses commercially available C9-depleted serum as reagent for C9. The specificity of the assay was verified by rapid, activity-guided isolation of the haemolytic component from human serum using high-performance liquid chromatography (HPLC) on a system for fast protein liquid chromatography. This isolation yielded a single component with characteristics of C9. The results suggest that rapid, activity-guided isolation as a new application of HPLC can be a useful tool to demonstrate the specificity of a functional assay.