Intra-venous digital subtraction angiography: an alternative method to intra-arterial digital subtraction angiography for experimental aneurysm imaging
Related Experiment Video
Updated: Aug 16, 2026

Fluorescence Angiography for Evaluation of Aneurysm Perfusion and Parent Artery Patency in Rat and Rabbit Aneurysm Models
Published on: July 24, 2019
Yong Hong Ding1, Daying Dai, Debra A Lewis
1Neuroradiology Research Laboratory, Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, Minnesota, MN 55905, USA.
Abstract:
Conventional intra-arterial digital subtraction angiography (IADSA), which necessitates surgical exposure and ligation of the femoral artery, is an invasive and expensive method of evaluation for experimental elastase-induced aneurysms in rabbits. The purpose of this study was to examine and validate intra-venous digital subtraction angiography (IVDSA) as an alternative to IADSA by comparing their diagnostic accuracies. We performed both IVDSA and IADSA for 24 elastase-induced saccular aneurysms in a rabbit model, 1 month following creation. Aneurysm sizes (neck, width and height) from both the IVDSA and IADSA procedures were evaluated and measured. Comparison of the aneurysm sizes between IVDSA and IADSA were performed with the Wilcoxon paired signed-rank test. All the aneurysms were seen clearly in both the IVDSA and IADSA techniques. Mean sizes of the IVDSA aneurysm neck, width and height were 3.41 +/- 0.80 mm, 3.61 +/- 0.93 mm and 8.07 +/- 2.11 mm, respectively. Mean sizes of the IADSA aneurysm neck, width and height were 3.43 +/- 0.80 mm, 3.66 +/- 0.92 mm and 8.16 +/- 2.25 mm, respectively. No significant difference was found in the sizes of the aneurysm neck, width and height between the two groups (P = 0.311, P = 0.086 and P = 0.258, respectively). IVDSA appears to be an alternative method for evaluating elastase-induced aneurysms in rabbits.
More Related Videos
10:09Drug Treatment by Central Venous Catheter in a Mouse Model of Angiotensin II Induced Abdominal Aortic Aneurysm and Monitoring by 3D Ultrasound
Published on: August 4, 2022
09:00The Rabbit Blood-shunt Model for the Study of Acute and Late Sequelae of Subarachnoid Hemorrhage: Technical Aspects
Published on: October 2, 2014
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Hemodialysis I: Introduction
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...