Related Experiment Video
Updated: Aug 16, 2026

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Digitized QT dispersion by the Valsalva maneuver in hypertensive patients
Hee-Jeoung Yoon1, Seung-Won Jin, Jong-Min Lee
1Division of Cardiology, Department of Internal Medicine, The Catholic University of Korea College of Medicine, Seoul, Korea.
Background:
Hypertension is an important risk factor for sudden cardiac death, of which the incidence increases with increases in blood pressure. Prolonged QT dispersion has been identified to indicate increased risk of life-threatening ventricular arrhythmia and sudden cardiac death. In this study, QT dispersion was investigated in hypertensive patients during the strain phase of the Valsalva maneuver.
Methods:
The study population included 75 subjects: 25 with normal blood pressure (Control), 25 with stage I hypertension (Group A), and 25 with stage II hypertension (Group B). Electrocardiography for QT dispersion was recorded at 25 mm/sec paper speeds before and during the Valsalva maneuver.
Results:
The patients in Group B were significantly older than the controls (p<0.05). Differences in sex, smoking, diabetes, angina, and hyperlipidemia were not statistically significant between the three groups. The basal QT dispersion was 25.3 +/- 18.3 ms in the controls, 39.0 +/- 17.8 ms in Group A, and 36.8 +/- 18.8 ms in Group B. The QT dispersion was significantly higher in group A patients than the controls (p<0.05). In Group B only, a significant increase in QT dispersion was observed during the Valsalva maneuver, compared to conditions prior to the Valsalva maneuver (p<0.05).
Conclusion:
The conditions that increase intrathoracic pressure may increase QT dispersion and severe hypertensive patients should avoid these conditions.
Related Concept Videos
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

