Related Experiment Video
Updated: Aug 16, 2026

Intramucosal Inoculation of Squamous Cell Carcinoma Cells in Mice for Tumor Immune Profiling and Treatment Response Assessment
Published on: April 22, 2019
Update on 18F-fluorodeoxyglucose/positron emission tomography and positron emission tomography/computed tomography
Yusuf Menda1, Michael M Graham
1Department of Radiology, University of Iowa, Iowa City, IA 52242, USA. yusuf-menda@uiowa.edu
Abstract:
This article summarizes the recent literature in (18)F-fluorodeoxyglucose/positron emission tomography (FDG-PET) imaging of head and neck cancers and extends the previous review in this area by Schöder and Yeung in the July 2004 issue of Seminars in Nuclear Medicine. Positron emission tomography/computed tomography (PET-CT) imaging is now used widely but has not been adequately evaluated for head and neck cancer. Its accuracy in initial staging is better than CT but may be similar to magnetic resonance imaging. It is not sufficiently accurate in the N0 neck to rule out nodal metastases but may be appropriate if sentinel node mapping is performed in patients with PET studies showing no nodal disease. PET imaging is beginning to be used in radiotherapy treatment planning, where it makes a significant difference by identifying malignant normal size nodes, extent of viable tumor, and distant disease. PET continues to be useful in carcinoma of unknown primary in identification of the primary site. Overall success is around 27% after all other modalities have failed. FDG-PET is being used frequently to assess response to therapy and for surveillance thereafter. The major controversy is when to image after radiotherapy or combined chemo-radiotherapy. One month seems to be too early. The ideal time seems to be 3 to 4 months to avoid both false-positive and false-negative studies. The growing use of PET-CT studies in head and neck cancer will certainly make a significant difference in the treatment and outcome in this disease.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...