Clinical guide for audiologic tinnitus management I: Assessment
Related Experiment Video
Updated: Jul 9, 2026

A Low Cost Setup for Behavioral Audiometry in Rodents
Published on: October 16, 2012
James A Henry1, Tara L Zaugg, Martin A Schechter
1VA Medical Center, Portland, OR 97207, USA. james.henry@med.va.gov
Purpose:
This article is the first of 2 that present basic guidelines for audiologists to provide clinical management of tinnitus. The method, termed audiologic tinnitus management (ATM), was developed to incorporate management strategies that can be implemented most efficiently by audiologists.
Method:
Development of ATM has been drawn from the clinical and research experience of the authors and numerous audiologists. Certain elements of ATM are adapted from the methods of tinnitus masking and tinnitus retraining therapy. Procedures are described in the present article for performing the intake assessment, while the companion article (J. A. Henry, T. L. Zaugg, & M. A. Schechter, 2005) describes treatment methodology.
Results:
Development of ATM has resulted in defined procedures to conduct a basic tinnitus assessment that includes written questionnaires, an intake interview, audiologic evaluation, and a psychoacoustic assessment of tinnitus perceptual characteristics. If patients report a sound tolerance problem (hyperacusis), loudness discomfort levels are measured at audiometric frequencies. There are special procedures for selecting hearing aids, ear-level noise generators, combination devices (noise generator and hearing aid combined), and personal listening devices (i.e., portable radios and tape, CD, and MP3 players).
Conclusions:
This article explains each of these assessment components in detail. Adoption of the ATM assessment protocol by audiologists can contribute to the establishment of uniform procedures for the clinical management of tinnitus patients.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Increased pulse rate
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...
Tonsillitis II: Management