Fast and Accurate Exhaled Breath Ammonia Measurement
Published on: June 11, 2014
Breath ammonia testing for diagnosis of hepatic encephalopathy
Suja DuBois1, Sue Eng, Renuka Bhattacharya
1Department of Medicine, Division of Gastroenterology, University of Washington School of Medicine, Seattle, Washington 98108, USA.
Abstract:
Measurement of arterial ammonia has been used as a diagnostic test for hepatic encephalopathy, but obtaining an arterial specimen is an invasive procedure. The aim of this study was to evaluate the ability of a minimally invasive, highly sensitive optical sensing device to detect ammonia in the breath of patients with end-stage liver disease and to evaluate the correlation of breath ammonia levels, arterial ammonia levels, and psychometric testing. Fifteen subjects with liver cirrhosis and clinical evidence of hepatic encephalopathy underwent mini-mental status examination, number connection test, focused neurological examination, and arterial ammonia testing. On the same day, breath ammonia testing was performed using an apparatus that consists of a sensor (a thin membrane embedded with a pH-sensitive dye) attached to a fiberoptic apparatus that detects optical absorption. Helicobacter pylori testing was performed using the 14C urea breath test. A positive correlation was found between arterial ammonia level and time to complete the number connection test (r = 0.31, P = 0.03). However, a negative correlation was found between breath ammonia level and number connection testing (r = -0.55, P = 0.03). Furthermore, no correlation was found between breath and arterial ammonia levels (r = -0.005, P = 0.98). There is a significant correlation between the trailmaking test and arterial ammonia levels in patients with cirrhosis. However, no correlation was found between breath and arterial ammonia levels using the fiberoptic ammonia sensor apparatus in this small study.
Related Concept Videos
Hepatic Encephalopathy
Serum Laboratory Studies, Stool Test, Breath Test
Urea Cycle
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...